无码视频在线看_成调教视频人网站免费视频_日韩中文字幕永久无码_亚洲成av午夜电影

400-700-9998
歐美大地 Pipe Leakage
Pipe Leakage
Pra-Oil Leakage detection test
發(fā)布時(shí)間:2018-11-23 瀏覽次數(shù):1525 來源:歐美大地

The main aim has been to demonstrate the feasibility relative easy integration of this kind of innovative leakage detection system based on distributed fibre optic technology

The area available for the test has allowed the use of approx. 200m polyethylene pipeline buried under 1m of argillaceous soil. The leakage simulation was achieved by hot water injection in the soil through several valves at different positions along the pipe.

 

Aim of monitoring:

The main aim has been to demonstrate the feasibility relative easy integration of this kind of innovative leakage detection system based on distributed fibre optic technology


 

Main results:

The Smartec sensing cable was able to detect any simulated leakage, by localizing every single temperature variation within different border conditions.

INSTALLATION PERIOD TYPE OF SENSORS NUMBER OF SENSORS
2007 DiTeSt / DiTemp 2

Related Papers:

Pipeline Leakage Detection and Localization Using Distributed Fiber Optic Sensing, D. Inaudi, B. Glisic, A. Figini, R. Walder, Rio Pipeline Conference 2007, Rio de Janeiro, Brazil, October 2-4 – 2007
Detection And Localization of Micro-Leakages Using Distributed Fiber Optic Sensing, Daniele Inaudi, Riccardo Belli, Roberto Walder, 7th International Pipeline Conference, IPC2008, 29th September – 3rd October 2008 , Calgary, Alberta, Canada – 2008